Groundwater Utilization And Sustainability: A Case Study Of Pydibheemavaram Industrial Area, India
G.venkata Rao, R. Srinivasa Rao, P.kalpana, B.neelima Sri Priya
Paper ID IA-ICCAESYDN-14046-887 · Pages 1-7
Download PDF: Groundwater Utilization And Sustainability: A Case Study Of Pydibheemavaram Industrial Area, IndiaAbstract
The over extraction of groundwater from the coastal aquifers, result in reduction of groundwater resource and lowering of water level. In general, the depletion of groundwater level enhance the landward migration of saltwater wedge. Now a days the ground water extraction increases by year to year because increased population and industrialization. The ground water is the only source of irrigation, domestic and Industrial purposes at Pydibhimavaram industrial area, which is located in the coastal belt of Srikakulam district, India of Latitudes 18.145N 83.627E and Longitudes 18.099N 83.674E. The present study has been attempted to calculate amount of water getting recharged into this aquifer, status of rainfall pattern for the past two decades and the runoff is calculated by using Khosla’s formula with available rain fall and temperature in the study area. A decision support model has been developed on the basis of Monthly Extractions of the water from the ground through bore wells and the Net Recharge of the aquifer. It is concluded that the amount of extractions is exceeding the amount of recharge from May to October in a given year which will in turn damage the water balance in the subsurface layers. Keywords—Aquifer, decision support model, Groundwater extraction, Run off estimation and Rainfall.
-
Air Plasma Spraying Behaviour On Zro2 And Y2o3 Over Ni- Based Superalloy, At High Temperature And Its Effect On Tribological Characterisation - A Review
Subash Chandra Bose Somu, Mohammad Farooq Wani
Paper ID IA-ICMAESYD-14046-03 · Pages 8-12
Download PDF: Air Plasma Spraying Behaviour On Zro2 And Y2o3 Over Ni- Based Superalloy, At High Temperature And Its Effect On Tribological Characterisation - A ReviewAbstract
The studies were carried out using a high temperature version of the friction and wear test sophisticated machine which were performed at temperatures ranging from 25 ° C to 1000 ° C. The materials used in the experiments were Ni based superalloys of three different alloying compositions (with and without coatings). The coatings materials used on the base substrate of Ni based superalloys over were ZrO2, Y2O3, HfO2 coated through atmospheric plasma spraying techniques (APS) with the nominal compositions and desirable process parameters to influence on the properties of base substrate to improve in applications. The results prove both friction and wear of tribological behaviour of materials with the coatings are temperature dependent. The aim of this work is to obtain a better understanding of friction and wear mechanisms of Ni based superalloys at high temperature on the tribological pairs. The corresponding wear and friction obtained experimentally would show the wear resistance and thereby decrease in friction at high temperature. Hence the coating undergoes significant surface morphological changes when exposed to elevated temperatures, which are likely to influence greatly to its tribological behaviour accordingly. Keywords— Airplasma Spraying, Coating Materials, High Temperature Tribology, Ni-based Superalloy.
-
The Value Of Solar Salt Specific Heat Enhancement In Concentrated Solar Thermal Plants
Hamed Riazi, S. Saeed Mostafavi Tehrani, Robert A. Taylor
Paper ID IA-ICMAESYD-14046-05 · Pages 13-18
Download PDF: The Value Of Solar Salt Specific Heat Enhancement In Concentrated Solar Thermal PlantsAbstract
It has been recently reported that nanoparticle dispersions in molten salt mixtures can significantly enhance the specific heat capacity of the salt mixtures. Molten salt eutectics can be used as heat transfer fluids (HTF) and/or thermal energy storage (TES) in a concentrated solar thermal (CST) plant. For either purpose, enhancing their specific heat capacity can theoretically improve CST system performance. However, to date no literature has determined how advantageous an enhancement of specific heat might be in a CST system or its subcomponents. In addition, since there is a cost associated with this enhancement, it is imperative to investigate the net economic limitations and benefits. To address these issues, this paper analyses how HTF specific enhancements in the range of 5-200% influence the CST-tower plant components. The results imply that increasing the HTF specific heat can reduce the storage volume by up to 80%. It was also found that the solar field mass flow rate and parasitic loads can also be decreased by up to 90%, while the net power output of CST-tower plant can be increased by up to 3%. Of course, nanoparticles (or other) costly additives are required to achieve these enhancements. Thus, this study poses the question of what premium could be paid (above the base solar salt cost of 1USD/kg) and still obtain an economic advantage. It was found that if specific heat is enhanced by 30%, a 50% premium on the pure salt is justified. If, however, a specific heat enhancement of 120% is possible (the maximum reported in the literature); a 300% premium yields an economic break-even point. Ultimately, this study reveals that if i) long-term, stable enhancements of 30-120% are indeed possible via the addition of ~1% of nanoparticles and ii) if nanoparticles (e.g. < 30 nm silica spheres) can be mass produced at < 50-200 USD/kg, they will have a significant positive return on investment in CST applications. Keywords— Nanoparticle, Specific Heat Enhancement, Concentrated Solar Thermal.
-
An Efficicent Strategy For The Operation Of An Integrated Thermal Energy Storage Facility And CHP/DH Plant
S. Saeed Mostafavi Tehrani, Robert A. Taylor, Ardalan Shafiei Ghazani, Pouya Saberi
Paper ID IA-ICMAESYD-14046-1016 · Pages 19-25
Download PDF: An Efficicent Strategy For The Operation Of An Integrated Thermal Energy Storage Facility And CHP/DH PlantAbstract
Combined Heat and Power (CHP) systems are of interest for District Heating (DH) networks due to their high conversion efficiency. The main challenge in implementing CHP/DH systems is in matching the inherent dynamic demand of residential thermal demand. In fact, the large mismatch between production and consumption profiles is issue of concern. Thermal Energy Storage (TES) can be used to cope with this issue. The operational strategy of an integrated CHP with TES plays a significant role in profitability of the whole plant and, as such, necessitates precise study. In this paper, different options for the operation of an integrated CHP/DH with TES are investigated, all based on the same concept, sending a constant hourly amount of energy to the TES/DH. In order to find the best constant flow rate, the performance of the TES facility has been investigated numerically. To find the best operation strategy, the objective function in simulations was to minimize thermal energy dumping due to the following sources: thermal energy degradation in the thermocline hot water storage tank and/or thermal energy dumping due to uncertainty of thermal demand. In all scenarios, hourly thermal energy supply is set at a constant average value for each month, but is varied from one month to another. Moreover, the amount of supplied energy varies between design options as it only covers a certain percentage of the thermal demand. Based on the proposed method of operation, the hourly full load operation mode is dictated to the CHP plant. This has been shown to allow CHP to have its best energetic performance in all scenarios. The results show that the best constant hourly thermal energy that should be supplied to the TES/DH should be equal to the monthly average of the maximum thermal demand. Furthermore, policies with fewer mismatches have resulted in better thermal performance of TES. Since all alternatives have been compared based on the same TES capacity, the best energetic scenario also represents the best economically one. Keywords— Combined Heat and Power, Thermal Energy Storage, District Heating, Operation Strategy, Numerical simulations.
-
Geometric Optimization Of High Temperature Shell And Tube Latent Heat Thermal Energy Storage
S. Saeed Mostafavi Tehrani, Gonzalo Diarce, Robert A. Taylor, Pouya Saberi, Ardalan Shafiei Ghazani
Paper ID IA-ICMAESYD-14046-1229 · Pages 26-32
Download PDF: Geometric Optimization Of High Temperature Shell And Tube Latent Heat Thermal Energy StorageAbstract
A simple geometry shell and tube heat exchanger provides a straightforward design for near-term integration of latent heat thermal energy storage systems in concentrated solar thermal plants, but currently there is no literature available for this configuration in the 286-565 ˚C temperature range. Therefore, the objective of this work is to evaluate the potential of this configuration for CST-tower plants by proposing a proper design method. The work has been done by optimizing the main geometric parameters involved along with considering a market ready phase change material (H500 salt). The optimization consisted of fixing the PCM volume while varying the other geometric parameters simultaneously over a wide range. The goal was to achieve the highest amount of total stored/delivered energy in a certain amount of time with a minimum heat transfer surface area. For the selected PCM, the optimum area was found 36-63 m2.GJ-1 (0.12-0.22 m2.kWhth-1). The storage charging and discharging efficiency for the selected PCM over a cycle of continuous charging and discharging were found ~99% and 85%, respectively. The results also imply that the shell and tube LHTES system is technically competitive with the conventional two-tank molten salts because of its high efficiency. Keywords— High temperature, Phase change material, Optimization, Shell and tube tank
-
The Impacts Of Foreign Workers To Malaysian Tourism Sector
Badaruddin Mohamed, Sulisa Mohd Paisar, Farah Hanin Mohd Nain
Paper ID IA-ICSSHAUS-15046-1154 · Pages 33-35
Download PDF: The Impacts Of Foreign Workers To Malaysian Tourism SectorAbstract
The popularity of Malaysia as an important tourism destination in Asia, has not only attracted many foreign tourists, but also induced the arrivals of foreign workers to come and look for jobs in various economic sectors including the Malaysian hospitality sector. The growth of Malaysian tourism especially after the successful Visit Malaysia Year campaigns of 1990 and 1994, has increased the demand for skilled workers to work in the hotel construction industry and to serve the hotels once they are completed. The shortage of trained personnel in the hospitality sector is caused by high and instant demand by the tourism sector and made worst by the fact that many Malaysian graduates of tourism and hospitality move abroad looking for greener pastures like in Singapore, Dubai, and Hong Kong. The drive to further reduce operating costs by the Malaysian hospitality industry has further fueled the need for professional foreign workers from nearby countries such Bangladesh, Myanmar, Indonesia, Pakistan and others. This, measure, despite the fact that it supposed to be just a stop-gap action, is now irreversible. Instead of reducing the number of foreign workers, early 2016 sees a call for more foreign workers to be imported to serve in critical sectors such as the construction industry. This paper looks at the issues of the influx of foreign workers into Malaysian tourism and hospitality sector. Keywords— Migration, Foreign Workers, Tourism.