25TH IASTEM INTERNATIONAL CONFERENCE
Berlin, Germany 16-07-2016
ISBN 978-93-86083-57-9
6 papers
-
Conceptual Framework For Designing Sustainable Buildings: Environmental Assessment of Bibliotheca Alexandrina
Riham A. Ragheb
Paper ID IA-ICCAEBER-16076-01 · Pages 1-6
Download PDF: Conceptual Framework For Designing Sustainable Buildings: Environmental Assessment of Bibliotheca AlexandrinaAbstract
Buildings and the environment are inextricably linked. Water, land, energy and materials are all consumed in the construction and operation of a building. The built structure in turns becomes part of the physical environment, affecting the living conditions, social wellbeing and economic profile. This paper aims to propose a conceptual framework to evaluate the environmental impacts of sustainable buildings design and then measuring the sustainability of Bibliotheca Alexandrina in Alexandria. Egypt can benefit from this framework to develop its buildings in order to achieve the sustainability targets. Index Terms— Bibliotheca Alexandrina, conceptual framework, design, environmental impact, sustainability.
-
Solar Chimney For Enhanced Natural Ventilation Based on CFD-Simulation For a Housing Prototype in Alexandria, Egypt
Gehad M. Mekkawi, Rana Ali Elgendy
Paper ID IA-ICCAEBER-16076-1483 · Pages 7-12
Download PDF: Solar Chimney For Enhanced Natural Ventilation Based on CFD-Simulation For a Housing Prototype in Alexandria, EgyptAbstract
Natural ventilation is being increasingly proposed as an alternative passive technique for mechanical air conditioning ventilation, which could minimize the operation hours of active cooling solutions in Residential Buildings in hot regions like Egypt. This study investigates the effect of the solar chimney on the indoor thermal performance by CFD simulation for a room in a residential prototype in Alexandria, Egypt. The influence on the ventilation velocity and indoor operative air temperature affected by air gap widths is investigated based on a number of CFD Simulation results using DesignBuilder software. Results show that the thermal performance of the operative air temperature has been reduced by 0.81 C⁰ and air velocity of the room has been improved after introducing Solar Chimney by 50% at the hottest hour. This has shown that the solar chimney is useful and functions as a stack ventilation tool. Index Terms— CFD Simulation, Residential, Solar Chimney, Stack Ventilation, Thermal Performance.
-
A Study to Enhance the Performance of Historical Buildings in Alexandria, Egypt [Case Study: Faculty of Engineering Administration Building]
Ragy Aly El-Gendy, Merna Nabil Saad
Paper ID IA-ICCAEBER-16076-1514 · Pages 13-17
Download PDF: A Study to Enhance the Performance of Historical Buildings in Alexandria, Egypt [Case Study: Faculty of Engineering Administration Building]Abstract
The Historical buildings in Egypt are neglected, although their value and importance. It is a unique opportunity to reach higher levels of environmental performance and reduce energy consumption and CO2 emissions. Working in a sustainable way brings environmental, social and economic advantages. The main scope of this paper is to indicate the environmental prospects to evaluate the performance of the buildings. The Faculty of engineering in Alexandria is one of the most important historical buildings in Alexandria, as it was built in 1941 and it occupies every year more than three thousands student, it is located in one of the main roads in Alexandria (Abou Quer St.) close to Manshia district (downtown). To achieve this aim, simulation software’s (diva-for-rhino & Autodesk Vasari) were used to conduct a series of sensitivity analysis on a set of design parameters which influence the building performance, using low cost solutions and simple strategies for environmental treatments which is the method to assess the environmental performance of buildings and in decision-making for sustainable buildings. Index Terms— Energy, Day Lighting Performance, Sustainable Rehabilitation, Green Building Solutions, Energy Simulations.
-
Effect of Binder Type on Freeze Thaw Durability of Sifcon
Mehmet Canbaz, Kemal Armagan
Paper ID IA-ICCAEBER-16076-1652 · Pages 18-22
Download PDF: Effect of Binder Type on Freeze Thaw Durability of SifconAbstract
In the places which have high number of annual freeze thaw effects causes cracks in structural elements such as concrete. These cracks cause cement-based composites to lose its bearing capacity under mechanical loads as well as thermal effects like freeze-thaw. Different cement-based composites were researched in past years to resist these effects. But composites such as slurry infiltrated fiber concrete (SIFCON), homogeneous cement paste phase, causes cracks to occur, expand and disintegrate more easily. To prevent the spread and distribution of cracks in such composites, fiber elements and cement type should select very carefully. In this experimental study different type of cements were used in SIFCON production with steel fibers. As a result of cracks steel fibers with two different dimensions were used to investigate the effect of fiber length. In the binder phase Portland, puzzolonic and fly ash added cements were used. Produced prismatic specimens were exposed to 50, 75 and 100 cycles of freezing-thawing effects. As a result the effect of fiber length and binder type on SIFCON performance under freezing-thawing cycles were determined with examining the changes in unit weight, ultrasonic pulse velocity, bending strength, compressive strength. Index Terms— SIFCON, cement type, fly ash, freeze-thaw effect.
-
Evaluation Comparative of Anti-Clogging Drip Emitters Design
Ali Abdulqader Mohammed Ali
Paper ID IA-ICSTMGER-16076-01 · Pages 23-24
Download PDF: Evaluation Comparative of Anti-Clogging Drip Emitters DesignAbstract
The drip irrigation systems have been a common irrigation method in the world due to the shortage of water in wide areas. Dripper is the key factor of drip irrigation systems, that deliver slow and uniformity water to the plants. The drippers can be suffering from clogging due to escape some particles of sand from the filters. The emitter clogging problem has a significant effect on the drip irrigation system efficiency. In this study, computer aid design, CAD was used to design a new anti-clogging emitter. The water flow behavior in the diaper was simulated by using two phases –CFD analysis to confirm the new design can provide the lowest chance to block. Comparative the simulation results for the new driver with the simulation results for three drip emitter design include eddy channel, pre-depositing channel and round-flow channel, it is clearly seen that the new design has a better ability to resist the clogging. Additionally, CFD simulation results introduce a good observation about the relation between the pressure applied and the water flow rate. This result was obtained due to the integration of the characteristic of great sieving and good pressure dropping in the new designed drip emitter. Keywords— Evaluation, simulation, drippers, CFD analysis.
-
Formulation Development of a Non-Ionic Surfactant Vesicles of Gemcitabine For Pulmonary Delivery
Fatima Al-Gawhari
Paper ID IA-ICSTMGER-16076-02 · Pages 25-27
Download PDF: Formulation Development of a Non-Ionic Surfactant Vesicles of Gemcitabine For Pulmonary DeliveryAbstract
Lung cancer is a major cause of death in the world. Cancer chemotherapy is limited by adverse toxicities to normal tissues. Targeted delivery of anticancer drugs to lung cancer by inhalation would help to reduce these toxicities. Lipid based delivery systems have been shown to be effective in improving the delivery of a number of drugs and the potential of using non-ionic surfactant vesicles (NIV) to improve the delivery of Gemcitabine (Gem) was studied in this research.The NIV was used to encapsulate Gem (Gem-NIV) for delivery by the pulmonary route. The NIV was prepared using concentrations of lipid (30 and 60 mM) and characterized on the basis of size, drug entrapment efficiency and zeta potential. In vivo pulmonary delivery of Gem-NIV was evaluated using two rodent models (BALB/c mice and Sprague-Dawley rats). The drug delivery study showed that inhalation of Gem treatments (both Gem and Gem-NIV) to mice resulted in high lung concentrations of Gem. The Gem lung level was higher for Gem-NIV (60 mM) treated mice at dose 14 mg/ml (0.5ml) compared with the same dose of Gem solution. In the rats, there was a greater accumulation of the Gem in the lungs of rats in comparison with other organs when administered as a NIV formulation prepared with 60 mM lipid at a dose of Gem of 6 mg/kg in comparison with NIV prepared with 30 mM. The results of these studies indicate that Gem-NIV show significant potential to improve delivery of Gem for the treatment of lung cancer using pulmonary administration compared with Gem solution alone. Keywords— Pulmonary, Gemcitabine and non-ionic surfactant vesicles.