A COMPREHENSIVE STUDY OF BITUMINOUS COAL TO THE COAL FINENESS PERFORMANCE AT THERMAL COAL PLANT
MOHD ZUL AMZAR ZULKIFLI, SALMI SAMSUDDIN
Paper ID IA-ICMAEKOTA-201025-17072A · Pages 20
Download PDF: A COMPREHENSIVE STUDY OF BITUMINOUS COAL TO THE COAL FINENESS PERFORMANCE AT THERMAL COAL PLANTAbstract
Bituminous coal remains the predominant fuel in pulverized coal–fired (PC) thermal power plants due to its favourable balance of calorific value, grindability, and combustion properties. Among the critical parameters influencing plant efficiency, coal fineness plays a decisive role in determining combustion stability, boiler heat rate, and emission performance. This literature review examines the relationship between the characteristics of bituminous coal particularly calorific value, volatile matter, and Hardgrove Grindability Index (HGI) and the degree of coal fineness achieved in pulverizers. Studies consistently highlight that maintaining at least 70% of coal particles below 200 mesh (75 μm) significantly reduces unburnt carbon, enhances thermal efficiency, and minimizes pollutant formation. High calorific value coals with lower HGI require greater milling energy and finer grinding to ensure complete combustion, whereas low calorific value coals, though easier to pulverize, often pose challenges related to moisture content and drying capacity. Optimization strategies such as classifier tuning, dynamic classifiers, coal blending, and real-time monitoring systems are increasingly employed to achieve desired fineness under varying coal qualities. Overall, the findings affirm that coal fineness is a critical determinant of thermal plant performance, with direct implications for fuel efficiency, operational reliability, and environmental compliance. Keywords: Bituminous Coal, Coal Fineness, Pulveriser, Thermal Plant
-
PERFORMANCE ASSESSMENT AND COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF SUBMERSIBLE SUMP PUMP IN A POWER PLANT COOLING SYSTEM
CHONG SOON YONG, SALMI SAMSUDDIN
Paper ID IA-ICMAEKOTA-201025-17073A · Pages 21
Download PDF: PERFORMANCE ASSESSMENT AND COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF SUBMERSIBLE SUMP PUMP IN A POWER PLANT COOLING SYSTEMAbstract
In cooling water systems of thermal power plants, sump pumps are often affected by undesirable hydraulic phenomena such as surface and subsurface vortex formation, flow separation, and non-uniform velocity distribution, all of which compromise pump performance and reliability. This study investigates practical vortex mitigation strategies through both physical modeling and computational fluid dynamics (CFD) simulation. A 1:10 geometrically scaled sump pump model was constructed and tested under three water levels water low (LWL), medium water level(MWL), and high water level (HWL) with and without mitigation devices. Two key design modifications were evaluated: a rear-wall splitter, positioned at the back of the sump bay to interrupt recirculating boundary flows, and a conical vortex breaker with baffles installed beneath the bell mouth to dissipate rotational energy. Experimental velocity profile measurements and streamline visualizations were complemented by validated CFD simulations. Results show that the rear-wall splitter effectively suppresses free-surface vortex formation at LWL, while the conical vortex breaker ensures a uniform velocity distribution across intake elevations, eliminating low-velocity regions prone to vortex initiation. Both physical and numerical findings demonstrate that these structural interventions significantly improve sump hydraulics, providing reliable strategies for minimizing vortex formation and enhancing pump intake performance. Keywords - CFD, Submersible Sump Pump, Vortices, Vortex Breaker
-
AN INTEGRATED APPROACH TO MONITOR AND CONTROL OF EMISSION AND EFFLUENT AT A MALAYSIAN THERMAL POWER PLANT
MUHAMMAD IRFANBIN ZAINAL ABIDIN
Paper ID IA-ICMAEKOTA-201025-17080A · Pages 22
Download PDF: AN INTEGRATED APPROACH TO MONITOR AND CONTROL OF EMISSION AND EFFLUENT AT A MALAYSIAN THERMAL POWER PLANTAbstract
Coastal thermal power plants are significant anthropogenic point sources, requiring robust systems to mitigate their impact on urban and marine environments. This study presents a comprehensive performance assessment of thecriticalpollutioncontrol infrastructuresatone of the Malaysia thermalpower plant.Weevaluatetheintegratedeffectivenessofthe(1)ElectrostaticPrecipita- tor(ESP)foratmosphericparticulatematter(PM)abatement,(2)AshPondsys- tem for containing and treating solid waste leachate, (3) Industrial Wastewater Treatment Plant (IWWTP) for processing complex industrial effluents, and (4) OilyWaterSeparators(OWS)forpreventinghydrocarboncontamination.Byan- alyzing operational data, monitoring reports, and effluent quality, this research quantifies the removal efficienciesof keypollutants, includingPM, heavy metals, suspendedsolids,andoils/greases.Thefindingsdemonstratehowthismulti-bar- rierapproachis essentialfor minimizingthetransfer ofpollutants fromthe plant's operationstothesurroundingairandsensitivecoastalwaters of theKlangestu- ary.Thisintegratedapproachensurescomplianceandsustainableenvironmental management within the energy sector. Keywords – Urban Runoff Monitoring, Industrial Waste water Treatment, Ash, Air Pollution, Electrostatic Precipitator (ESP), Emission.